Humerus Neck Locking Compression Plate

Humerus Neck Locking Compression Plate

Humerus Neck Locking Compression Plate

 Thickness:1-120mm
 Width:1500-3600mm
 Length:as custom's request
 Technique:Cold rolled or hot rolled
 Surface treatment:Bare/Shot Blasted and Spray Paint or as required.
 Standard:ASTM,EN,GB,JIS,DIN

Internal Fixation of Proximal Humerus Fracture with ...

Sep 25, 2018· PDF | On Sep 23, 2018, Chul-Hyun Park and others published Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate

The use of locking plates in proximal humeral fractures ...

ncbi.nlm.nih.gov› …› v.3(4); Oct-Dec 2009The use of locking plates in proximal humeral fractures: Comparison of outcome by patient age and fracture pattern ... The normal anatomic neck-shaft angle of the humerus is considered to be ... Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for ...[PDF]

3.5 mm LCP Periarticular Proximal Humerus Plate. Part …

3.5 mm LCP Periarticular Proximal Humerus Plate 2 AO Principles 4 ... Small Fragment Locking Compression Plate (LCP) System Technique Guide. ... Insert a locking screw in one of the two neck holes in the head of the plate. Control the height of the plate in the AP[PDF]

Proximal Humerus Locking Plate - University of …

3.5mm & 4.5mm Proximal Humerus Locking PlatesCatalog Infor Table of Contents ... 1mm of compression or locking. 5 Implant Features 4.5mm Proximal Humerus Plate ... placement of the plate. Surgical neck fracture reduction may be accomplished using an anatomically contoured[PDF]

Part of the DePuy Synthes Locking Compression Plate …

LCP Periarticular Proximal Humerus Plate System in the MR environment is unknown. ... Part of the DePuy Synthes Locking Compression Plate (LCP) System. ... Insert a locking screw in one of the two neck holes in the head of the plate. Control the height of the plate in the AP[PDF]

Zimmer® Periarticular Proximal Humeral Locking Plate ...

allow bi-directional compression The locking plate design does not ... anatomical or surgical neck of the humerus. Recommended X-rays AP View ... Zimmer Periarticular Proximal Humeral Locking Plate 5 Fig. 3 On the distal shaft, especially in comminuted fractures, the insertions

Outcomes for four-part proximal humerus fractures treated ...

Outcomes for four-part proximal humerus fractures treated with a locking compression plate and an autologous iliac bone impaction graft

Locking Plate Fixation for Proximal Humerus Fractures

Locking Plate Fixation for Proximal Humerus Fractures ... Four-part fractures of the neck of the humerus. ... et al. Analysis of early failure of the locking compression plate in osteoporotic ...

Locking Plate for Proximal Humeral Fracture in the Elderly ...

ncbi.nlm.nih.gov› …› Clin Orthop Surg› v.4(3); 2012 SepLocking Plate for Proximal Humeral Fracture in the Elderly Population: Serial Change of Neck Shaft Angle. Aditya C Pawaskar, MD, Kee-Won Lee, ... One of the most recent developments is the locking compression plate (LCP). ... the proximal humerus locking plate offers a reliable option to the surgeon in order to treat these types of fractures in ...

Current concepts in locking plate fixation of proximal ...

Current concepts in locking plate fixation of proximal humerus fractures ... the following principles have become important in order to increase the stability of locking plate fixation of proximal humerus fractures. ... Apostolou CD, Taneja T, Korres DS, Amini A. Fixation of proximal humerus fractures using the PHILOS plate. Clin Orthop Relat ...[PDF]

Comparison study of the clinical effect and biomechanics ...

compression plate and interlocking intramedullary nail for humerus shaft fracture. ... humerus surgical neck and 2 cm to humerus epicondyle in ... Comparison study of the clinical effect and biomechanics between locking compression plate and interlocking *

Fractured Humerus. Upper Arm Bone Breaks and treatment ...

A Fractured Humerus is common and may result from injury. Read about how to diagnose and treat a Fractured Humerus ... The anatomical neck separates the greater and lesser tuberosities from the humeral head. The long head of biceps runs between the tuberosities in the bicipital groove, and the surgical neck is just below the greater and lesser ...

Proximal Humerus Fractures - MoveForwardPT

A proximal humerus fracture is a serious injury to the humerus bone in the shoulder joint that requires immediate treatment to preserve function of the shoulder. A fracture to the humerus bone is a possible consequence of a traumatic event, such as a fall or forceful collision. Depending on the ...

Proximal Humerus Fractures Treatment & Management ...

Aug 24, 2017· Proximal Humerus Fractures Treatment & Management. Updated: Aug 24, 2017 ... authors’ preferred technique is an open reduction through the deltopectoral approach using a precontoured proximal humerus locking plate for fixation. ... place proper padding where necessary to avoid compression of neurovascular structures (eg, by straps[PDF]

OptiLock Upper Extremity Plating System Proximal …

Upper Extremity Plating System Proximal Humeral Plates ... The OptiLock Upper Extremity Plating System is intended for fixation of fractures and osteotomies. ... This low profile locking plate is designed to be placed approximately 10-15mm distal to the rotator cuff attachment

(PDF) Locking Plate Fixation for Proximal Humerus Fractures

Locking Plate Fixation for Proximal Humerus Fractures. ... neck of the humerus. J Bone Joint Surg Br. 1984; 66(1):104-108. ... early failure of the locking compression plate .

Fixation of complex proximal humeral fractures in elderly ...

J.M. Bjorkenheim, J. Pajarinen, V. SavolainenInternal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year

Operative Treatment of 2-Part Surgical Neck Fracture of ...

journals.lww› Home› September 2017 - Volume 31 - Issue 9Operative Treatment of 2-Part Surgical Neck Fracture of the Humerus: Intramedullary Nail Versus Locking Compression Plate With Technical Consideration Lee, Wonyong MD *; Park, Jun-Young MD †; Chun, Yong-Min MD, PhD *

Two-part surgical neck fractures of the proximal part of ...

Two-part surgical neck fractures of the proximal part of the humerus: A biomechanical evaluation of two fixation techniques[PDF]

Clinical outcomes of allograft with locking compression ...

Clinical outcomes of allograft with locking compression plates for elderly four-part proximal humerus fractures Hua Chen, Xinran Ji, ... locking compression plate (LCP) demonstrates ... continuation and the normal neck shaft angle were re-stored. To prevent damaging the vascular supply to the

Proximal humerus fractures operated with PHILOS plate: …

Proximal humerus fractures operated with PHILOS plate: 4 year prospective study ... study is conducted to study the results and complications of proximal humeral fractures treated by anatomic locking compression plate (PHILOS- proximal humerus interlocking system) and PHLP- Pro. ... the anatomic locking compression plate is suitable for the ...

Reducing Postoperative Fracture Displacement After Locked ...

Despite its reported complications, proximal humerus locked plating remains the most widely used type of fixation. 1 Advancements in locking plate design, improved understanding of fixation principles, and adoption of techniques augmenting proximal humerus locking plate fixation, particularly in osteoporotic bone, have reduced postoperative ...

Two-part surgical neck fractures of the proximal part of ...

Background: Successful internal fixation of fractures of the surgical neck of the humerus can be difficult to achieve because of osteopenia of the proximal aspect of the humerus. The purpose of this study was to compare the biomechanical stability of a proximal humeral intramedullary nail and a locking plate for the treatment of a comminuted ...

Compression plate, Compression LCP - All medical device ...

medicalexpo› Traumatologyneck without any backing out of the screws into the soft tissues. Linking these distal and proximal screws with a locking plate gives a much more stable construction with superior rotational stability than would be found ... humerus compression plate / proximal Alians Proximal Humerus . ...

CN201564586U - Locking proximal humerus plate - Google …

The utility model discloses a locking proximal humerus plate, which comprises a steel plate body; a plurality of first combination holes, a plurality of suture holes and a plurality of distal end fixing hole are formed on the steel plate body; and at least two second combination holes are respectively formed on extension arms. Due to the adoption of the technical scheme, greater tubercle ...
GET IN TOUCH

We receive enquiries in English, Español (Spanish), Русский язык (Russian), Français (French) and العربية (Arabic). Our professional team will reply to you within one business day. Please feel FREE to contact us!